INTERPRETATION 95-18
Subject: Scope and Applicability
Edition: 1992
Addendum: 1994
Question 1: Is it a requirement of the NBIC that the rules of Appendix C-NR be applied to any repair or modification performed on an ASME Section III N-Stamped item, even though the installed item is not located in a Class 1, 2, or 3 system within the ASME Section XI Program boundaries established by the Owner in accordance with regulatory safety system classification so as to maintain its ASME Section III Code integrity?
Reply 1: No. The rules of Appendix C-NR are not required for repairs or modifications to ASME Section III items installed outside of ASME Section XI system boundaries.
Question 2: Is it a requirement of the NBIC that any work performed on an item prior to its installation in a Class 1, 2, or 3 system within the ASME Section XI Program be performed under the rules of Appendix C-NR?
Reply 2: Yes. Upon completion of the construction Code, any repairs or modifications of an item intended for service in an ASME Section XI system must be performed under the rules of Appendix C-NR to maintain the Code integrity of the item.
Question 3: Is it permissible for the owner to reuse an ASME Section III N-Stamped item that was installed in a location not within the ASME Section XI Class 1, 2, or 3 system, provided all work performed on the item was in accordance with the rules of Appendix C-NR?
Reply 3: Yes. Under the described conditions, the Code integrity would be maintained for possible reuse of the item in an ASME Section XI Class 1, 2, or 3 system application.
Question 4: Under the requirements of Appendix C-NR, is it permissible for the owner to reuse an ASME Section III N-Stamped item that was installed in a location not within the ASME Section XI Class 1, 2, or 3 system even though work had been performed on the item outside the rules of Appendix C-NR?
Reply 4: No. An item on which repair or modification activities have been performed outside of the rules of Appendix C-NR may not be subsequently used in an application which requires compliance with the rules of Appendix C-NR.